Marjon Borgert

153 Implementation of care bundles in ICUs τ = − 0.189 0 10 20 30 40 50 60 70 80 90 100 Per 2 weeks Per month Per quarter Per 6 months Per year More than 1 year time frame compliance measurement Level of compliance in % Overall 0 10 20 30 40 50 60 70 80 90 100 Per 2 weeks Per month Per quarter Per 6 months Per year More than 1 year time frame compliance measurement Level of compliance in % Central line bundle τ = − 0.136 0 10 20 30 40 50 60 70 80 90 100 Per 2 weeks Per month Per quarter Per 6 months Per year More than 1 year time frame compliance measurement Level of compliance in % Ventilator bundle τ = 0.701 0 10 20 30 40 50 60 70 80 90 100 Per 2 weeks Per month Per quarter Per 6 months Per year More than 1 year time frame compliance measurement Level of compliance in % Sepsis bundle Time frame: Prospective cohort & compliance calculated by AON−approach Figure S6. Relation between compliance and time frame in which compliance is measured. For the ventilator bundle as well as the central line bundle, compliance is mostly calculated per months and in some studies quarterly. For these studies relatively high compliance levels were measured. Only for the sepsis bundle long time frames were used in which compliance is calculated. However, overall, there is no relation between the time frame and compliance (τ = -189, p = 0.417), neither for each bundle separately: ventilator bundle: τ = -0.136, p = 0.767; sepsis bundle: τ = 0.701, p = 0.064). Correlation coe cients could not be determined for the central line bundle due to the small number of observations.

RkJQdWJsaXNoZXIy MTk4NDMw