Elise Neppelenbroek

43 Observer agreement of aCTG assessments Table S2 Intraobserver agreement in various FIGO components of antenatal CTGs for professional groups in maternity care using proportions of agreement. Proportions of agreement (95% CI) Primary care midwives Hospital-based midwives Residents Obstetricians Baseline heart frequency 0.96 (0.67-1.00) 0.95 (0.67-0.99) 0.96 (0.69-1,00) 0.95 (0.66-1.00) Variability 0.92 (0.62-0.99) 0.88 (0.59-0.98) 0.90 (0.61-0.98) 0.85 (0.54-0.96) Accelerations 0.94 (0.64-0.99) 0.83 (0.54-0.96) 0.91 (0.62-0.98) 0.84 (0.53-0.96) Decelerations 0.88 (0.57-0.97) 0.89 (0.60-0.98) 0.87 (0.58-0.97) 0.89 (0.59-0.98) Contractions 0.83 (0.52-0.96) 0.88 (0.59-0.98) 0.88 (0.59-0.97) 0.86 (0.55-0.97) CTG, cardiotocography; FIGO, International Federation of Gynecology and Obstetrics; CI, confidence interval. 2