lxiv Table 2.S10 Patient Flow and Timing: Risk of Bias and Applicability Author, Year Any patients that did not receive MRI or pathology or excluded from 2 x 2 table? Interval/int ervention between MRI and histopathol ogical diagnosis Appropriate interval between MRI and histopatholo gy? All patients received (the same) histopathology diagnosis? All patients included in analysis? Potential for bias in patient flow? Ascher et al. 1994 No. NR Unclear No, some diagnosed by biopsy and others by hysterectomy Yes Low Badawy et al. 2014 No. NR Unclear Yes Yes Low Bazot et al. 2001 No. NR Unclear Yes Yes Low Bazot et al. 2003 No NR Unclear Yes Yes Unclear Dueholm et al. 2001 No 2 weeks Yes Yes Yes Low Hamimi et al. 2015 No. NR Unclear No, patients received different methods of reference diagnosis Yes Unclear Hricak et al. 1992 No NR Unclear Unclear Yes Unclear Masui et al. 2003 No NR Unclear Unclear Yes Low Moghadam et al. 2006 Unclear NR Unclear Yes Yes Low Phillips et al. 1996 No NR Unclear No, some had transabdominal biopsy Yes Unclear Reinholdt et al. 1996 No 14 days Yes Yes Yes Low Stamatopoulo s et al. 2012 NR NR Unclear Yes Yes Low Tellum et al. 2019 No NR Unclear Yes Yes Low Tian et al. 2016 No NR Unclear Yes Yes Low NR: not reported